Skip navigation
EPR Center Banner

EPR Center

Low Frequency Papers

Frequency Dependence of EPR Signal-to-Noise, G. A. Rinard, R. W. Quine, J. R. Harbridge, R. Song, G. R. Eaton, and S. S. Eaton, J. Magn. Reson. 140, 218-227 (1999).

An L-band Crossed-Loop (Bimodal) Resonator, G. A. Rinard, R. W. Quine, and G. R. Eaton, J. Magn. Reson. 144, 85-88 (2000).

Frequency Dependence of Electron Spin Relaxation for Three S=1/2 Species Doped into Diamagnetic Solid Hosts, S. S. Eaton, J. Harbridge, G. A. Rinard, G. R. Eaton and R. T. Weber, Appl. Magn. Reson. 20, 151-157 (2001).

Electron Spin Relaxation of Triarylmethyl Radicals in Fluid Solution, L. Yong, J. Harbridge, R. W. Quine, G. A. Rinard, S. S. Eaton, G. R. Eaton, C. Mailer, E. Barth, and H. J. Halpern, J. Magn. Reson. 152, 156-161 (2001).

Multifrequency EPR of Ultramarine Blue, G. R. Eaton, S. S. Eaton, J. W. Stoner, R. W. Quine, G. A. Rinard, A. I. Smirnov, R. T. Weber, J. Krzystek, A. K. Hassan, L.-C. Brunel, and A. Demortier, Appl. Magn. Reson. 21, 563-570 (2001).

Frequency Dependence of EPR Signal Intensity, 248 MHz to 1.4 GHz, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 154, 80-84 (2002).

250 MHz Crossed Loop Resonator for Pulsed Electron Paramagnetic Resonance, G. A. Rinard, R. W. Quine, G. R. Eaton, and S. S. Eaton, Magn. Reson. Engineer. 15, 37-46 (2002).

Adapting a Hall Probe Controller for Current Control of an Air-Core Magnet, G. A. Rinard, R. W. Quine, G. R. Eaton, and S. S. Eaton, Magn. Reson. Engineer. 15, 47-50 (2002).

Magnet and Gradient Coil System for Low-Field EPR Imaging, G. A. Rinard, R. W. Quine, S. S. Eaton, G. R. Eaton, E. D. Barth, C. A. Pelizzari, and H. J. Halpern, Magn. Reson. Engineer. 15, 51-58 (2002).

A Pulsed and Continuous Wave 250 MHz Electron Paramagnetic Resonance Spectrometer, R. W. Quine, G. A. Rinard, S. S. Eaton, G. R. Eaton, Magn. Reson. Engineer. 15, 59-91 (2002).

Frequency Dependence of EPR Signal Intensity, 250 MHz to 9.1 GHz, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 156, 113-121 (2002).

Frequency Dependence of EPR Sensitivity, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, Biological Magnetic Resonance, C. Bender and L. J. Berliner, eds. 21, 115-154 (2004).

EPR Spectrometers at Frequencies Below X-band, G. R. Eaton and S. S. Eaton, Biological Magnetic Resonance, C. Bender and L. J. Berliner, eds. 21, 59-114 (2004).

Frequency Dependence of Electron Spin Relaxation of Nitroxyl Radicals in Fluid Solution, R. Owenius, G. E. Terry, M. J. Williams, S. S. Eaton, and G. R. Eaton, J. Phys. Chem. B, 108, 9475-9481 (2004).

Direct-detected rapid-scan EPR at 250 MHz, J. W. Stoner, D. Szymanski, S. S. Eaton, R. W. Quine, G. A. Rinard, and G. R. Eaton, J. Magn. Reson. 170, 127-135 (2004).

Frequency (250 MHz to 9.2 GHz) and Viscosity Dependence of Electron Spin Relaxation of Triarylmethyl Radicals at Room Temperature, R. Owenius, G. R. Eaton, and S. S. Eaton, J. Magn. Reson. 172, 168-175 (2005).

Multifrequency EPR of Four Triarylmethyl Radicals, A. J. Fielding, P. J. Carl, G. R. Eaton, and S. S. Eaton, Appl. Magn. Reson. 28, 231-238 (2005).

Rapid-Scan EPR with Triangular Scans and Fourier Deconvolution to Recover the Slow-Scan Spectrum, J. P. Joshi, J. R. Ballard, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 175, 44-51 (2005).

Pulsed Saturation Recovery 250 MHz Electron Paramagnetic Resonance Spectrometer, R. W. Quine, S. S. Eaton, and G. R. Eaton, Conc. Magn. Reson. B (Magn. Reson. Engin.) 26B, 23-27 (2005).

Fast-Response VHF Pulsed Power Amplifiers, R. W. Quine, G. R. Eaton, S. Dillon, and D. Myer, Conc. Magn. Reson. B (Magn. Reson. Engin.) 27B, 1-7 (2005).

Fast-Response VHF Pulsed 2 KW Power Amplifiers, R. W. Quine, G. R. Eaton, and S. Dillon, Conc. Magn. Reson. B (Magn. Reson. Engin.) 29B, 185-190 (2006).

Electron Spin T2 of a Nitroxyl Radical at 250 MHz Measured by Rapid Scan EPR, M. Tseitlin, A. Dhami, R. W. Quine, G. A. Rinard, S. S. Eaton, and G. R. Eaton, Appl. Magn. Reson. 30, 651-656 (2006).

A Linear Magnetic Field Scan Driver, R. W. Quine, T. Czechowski, and G. R. Eaton, Conc. Magn. Reson. B (Magn. Reson. Engin.) 35B, 44-58 (2009).

A Wire Crossed-Loop-Resonator for Rapid Scan EPR, G. A. Rinard, R. W. Quine, J. R. Biller, and G. R. Eaton, Concepts Magn. Reson. B, (Magn. Reson. Engin.) 37B, 86-91 (2010).

A Very Fast Switched Attenuator Circuit for Microwave and R.F. Applications, R. W. Quine, M. Tseytlin, S. S. Eaton, and G. R. Eaton, Conc. Magn. Reson. B, Magn. Reson. Engineer, 37B, 39-44 (2010).

Quantitative Rapid Scan EPR Spectroscopy at 258 MHz, R. W. Quine, G. A. Rinard, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 205, 23-27 (2010).

Use of the Frank Sequence in Pulsed EPR, M. Tseitlin, R. W. Quine, S. S. Eaton, G. R. Eaton, H. J. Halpern, and J. H. Ardenkjaer-Larsen, J. Magn. Reson. 209, 306-309 (2011).

Rapid Frequency Scan EPR, M. Tseitlin, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 211, 156-161 (2011).

Use of polyphase continuous excitation based on the Frank sequence for EPR, M. Tseitlin, R. W. Quine, S. S. Eaton, G. R. Eaton, J. Magn. Reson. 211, 221-227 (2011).

Digital EPR with an arbitrary waveform generator and direct detection at the carrier frequency, M. Tseitlin, R. W. Quine, G. A. Rinard, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 213, 119-125 (2011).

Multi-frequency EPR Sensitivity, G. A. Rinard, R. W. Quine, S. S. Eaton, and G. R. Eaton, in Multifrequency Electron Paramagnetic Resonance: Theory and Applications, S. K. Misra, Ed., Ch. 5.2, Wiley-VCH, 2011.

Frequency Dependence of Electron Spin Relaxation Times in Aqueous Solution for a Nitronyl Nitroxide Radical and Per-deuterated-Tempone between 250 MHz and 34 GHz, J. R. Biller, V. M. Meyer, H. Elajaili, G. M. Rosen, S. S. Eaton, and G. R. Eaton, J. Magn. Reson. 225, 52 – 57 (2012).